Meet-me room
The meet-me room is where networks meet. Carriers, and sometimes customers, have their panels there; the operator links them to each other with cross-connects, without traffic leaving the site.
What it is for
Without a meet-me room, linking two networks means running a circuit across the city. With one, the link stays inside the site and takes a few tens to a few hundred metres of fibre, depending on the size of the campus. That is what lets a tenant reach several carriers, several cloud providers, Internet exchange points (IXPs) and its own partners from a single rack.

What you find there
- Optical panels and drawers
Each carrier, and sometimes each customer, has its own panels there; every port is identified by a label.
- Dedicated cable trays
Links arrive there from the rooms and leave by separate trays, often fibre.
- Separate entrances
Carriers enter the building by different entrances, and the room is often duplicated, so that one incident does not cut the whole site.
- Controlled access
The operator decides who comes in, when and with whom. Rules depend on the site.
- Several rooms on a large campus
Large campuses often have several, for link redundancy.
How links are set up
The carrier brings its circuits onto its panels. A customer that wants to connect orders a cross-connect from the operator, with authorisation from the party that holds the target port (the letter known as LOA-CFA). The operator, or a team it appoints, then installs the patch cord between the two panels. The customer generally sees only the result: a link coming up in its rack.
Meet-me room and standards
ANSI/TIA-942-C uses “entrance room” for the room where carriers arrive; the meet-me room is the shared version of it in a colocation data centre. In Europe, ISO/IEC 11801-5 and EN 50173-5 use “external network interface” for this meeting point between carrier networks and the site cabling.
In a data centre, on the operator’s or tenant’s instruction
Patching between panels, connector inspection and cleaning, labelling, link testing, patching plan updates: these are tasks we carry out in Île-de-France data centres, on the instruction of the operator or tenant and under its access rules. Every intervention, however short, is followed by a documented report, with photos of your rack, in line with the site’s photo policy.
Content written by the Full Connection field team and approved by Karim Bouacida, head of the company.
Frequently asked questions
Can a customer access the meet-me room themselves?
Rarely. Access is restricted and managed by the operator, who most often installs cross-connects itself or has them installed. The detail depends on the site and its rules.
How is it different from a computer room?
The computer room houses customers’ active equipment. The meet-me room is mainly a room of panels and optical drawers, with, depending on the site, carrier racks and their active equipment: it is the point where links cross.
Can two neighbouring racks be linked without going through the meet-me room?
Within the same cage, yes, directly. Between two cages or two rooms, even for a single customer, most operators require a cross-connect ordered from them. The meet-me room is for linking different customers or carriers.
Why does a data centre often have several meet-me rooms?
For redundancy. Carriers enter at different points and the room is duplicated: if one is hit by an incident, the links ordered through the other room stay in service, provided separate paths were ordered.
How does it relate to an Internet exchange point?
An exchange point (IXP) often has its equipment in the data centre and connects to carriers and customers by cross-connects, like direct access to cloud providers.
Links to install or rework in a meet-me room?
Describe the site, the window and the objective.